Sectors

Restaurants, cafés & food service

The most expensive square feet in commercial real estate, and the easiest to underestimate. Hood routes, grease, restrooms and occupant load decide whether a site works.

Café dining room with a fluted central column, pendant lights and banquette seating

2026 restaurant build-out costs

ItemBenchmark
Restaurant / food service, overall$175 – $700+ / SF
Casual dining$200 – $450 / SF
Fine dining / complex$450 – $800+ / SF
Back-of-house kitchen & MEP25% – 35% of budget
Front-of-house finishes40% – 50% of budget

Source: Meade Design 2025–2026 U.S. fit-out benchmarks.

Infrastructure line items

Line itemInstalled cost
Type I exhaust hood + make-up air$20,000 – $55,000+
Wet-chemical fire suppression$3,000 – $8,000
Indoor hydromechanical grease interceptor$1,000 – $3,500
Automatic grease removal unit (AGRU)$4,000 – $8,000+
In-ground gravity interceptor$5,000 – $15,000+
ADA restroom, single$15,000 – $45,000+

Source: Meade Design 2025–2026 U.S. fit-out benchmarks. Hoods run ≈ $4,000–$5,000 per linear foot installed.

Type I hood and the duct route

Fryers, ranges, griddles and charbroilers require a Type I hood (IMC § 507, NFPA 96) with a welded grease duct, make-up air and wet-chemical suppression (IBC § 904). Before you sign, confirm that a duct can reach the roof with required clearances — through tenant space above, a shaft, or an exterior wall the landlord will allow. Second-generation restaurants with an existing hood still need it checked for length, listing and condition.

Grease interceptors

The local sewer authority sets the interceptor type and size. Indoor hydromechanical units suit small cafés; high-volume kitchens are often required to install an in-ground gravity vault, which means exterior excavation and landlord approval.

Health department review

Food service plans go to the local health department in parallel with the building permit: equipment schedule, finish schedule, hand sinks, three-compartment and mop sinks, and dry and cold storage. Missing equipment cut sheets are the most common reason for delay.

The 49-occupant A-2 threshold

Dining with tables and chairs is calculated at 15 SF net per occupant (IBC Table 1004.5). A 735 SF net dining room is 49 occupants; a 750 SF room is 50. At 50 the space generally needs a second exit and panic hardware; at 100, or above 5,000 SF of fire area, or on an upper floor, Group A-2 requires automatic sprinklers (IBC § 903.2.1.2). Restroom counts follow IBC Table 2902.1, and customers must have restroom access.

Test a retail-to-restaurant conversion in two minutes.

Occupancy & ADA checker

Have a suite under LOI?

Send the floor plan and the work letter. We will tell you what fits, what it costs and what the allowance leaves uncovered.

Request a Test Fit