Sectors
Medical, dental & wellness clinics
Clinics are plumbing, power and privacy projects that happen to have finishes. The suite you choose decides how much of the budget goes into the slab.

What clinic build-outs cost in 2026
| Item | Benchmark |
|---|---|
| General medical, dental & outpatient wellness | $150 – $350+ / SF |
| Specialty surgical & imaging | $500 – $750 / SF |
| Architectural & MEP design fees | $18 – $30+ / SF (11% – 15%) |
| Medical gas / dental vacuum & compressor rough-in | ≈ $25,000 allowance |
| ADA restroom, single | $15,000 – $45,000+ |
Source: Meade Design 2025–2026 U.S. fit-out benchmarks.
The cost drivers
Operatory and exam-room plumbing
Every dental operatory needs water, drain, vacuum and air at the chair; every exam room needs a hand sink. In a slab-on-grade suite, distance from the building’s sanitary line sets the trenching cost — a test fit that clusters wet rooms along the existing stack can save tens of thousands of dollars.
Vacuum, compressed air and medical gas
Dental vacuum pumps and compressors need a ventilated mechanical room and dedicated circuits. Procedures with nitrous oxide or oxygen piping bring NFPA 99 requirements, zone valves and alarms.
Radiation shielding
Intraoral X-ray, panoramic and CBCT units may require lead-lined walls or doors. Shielding is designed by a qualified physicist from the equipment specification and room layout — order it early, because it can change wall types.
Privacy and acoustics
HIPAA expects reasonable safeguards for spoken patient information. In practice: full-height insulated partitions at exam and consult rooms, solid-core doors, sound-rated ceilings and a reception layout where check-in conversations are not overheard.
Accessibility in exam rooms
Accessible exam rooms need clear floor space on the transfer side of the table, a 60-inch turning space and an accessible route from reception — the 2010 ADA Standards and the U.S. Access Board’s medical diagnostic equipment standards both shape the room size.
Code notes for clinics
Outpatient clinics are usually Group B, with an occupant load factor of 100 SF gross for outpatient areas. When four or more patients at a time are rendered incapable of self-preservation (general anesthesia, sedation), the suite becomes an ambulatory care facility with smoke compartments and sprinkler requirements. Moving a clinic into a former retail or warehouse suite is a change of occupancy.
Screen a clinic suite before the LOI is signed.
Occupancy & ADA checker